Vectors of names of member objects containing spectral transmittance data for Courtaulds di-acetate films of different thickness.
Details
1) Films (0.115 mm thick) stretched 25 cm below Q-Panel UVB313 lamps and exposed to UV radiation from different lengths of time per day. All films were installed and sampled at the same time inside a greenhouse. The digits give the number of minutes per day that the lamps were on.
2) New films of different thickness.
Note
Individual measurements of single samples, not a specification. Instrument used: Hewlett-Packard 8453 diode array spectrophotometer without an integrating sphere. These films are no longer available, but similar material from other suppliers may be still available.
Examples
courtaulds_filters
#> [1] "Courtaulds_CA_115um" "Courtaulds_CA_115um_age000"
#> [3] "Courtaulds_CA_115um_age020" "Courtaulds_CA_115um_age030"
#> [5] "Courtaulds_CA_115um_age060" "Courtaulds_CA_115um_age100"
#> [7] "Courtaulds_CA_115um_age180" "Courtaulds_CA_115um_age300"
#> [9] "Courtaulds_CA_250um" "Courtaulds_CA_480um"